Index by author
Edelman, R.R.
- Extracranial VascularOpen AccessNon-Contrast-Enhanced Carotid MRA: Clinical Evaluation of a Novel Ungated Radial Quiescent-Interval Slice-Selective MRA at 1.5TS. Peters, M. Huhndorf, U. Jensen-Kondering, N. Larsen, I. Koktzoglou, R.R. Edelman, J. Graessner, M. Both, O. Jansen and M. Salehi RaveshAmerican Journal of Neuroradiology September 2019, 40 (9) 1529-1537; DOI: https://doi.org/10.3174/ajnr.A6171
Eixarch, E.
- PediatricsOpen AccessGlobal and Regional Changes in Cortical Development Assessed by MRI in Fetuses with Isolated Nonsevere Ventriculomegaly Correlate with Neonatal NeurobehaviorN. Hahner, O.M. Benkarim, M. Aertsen, M. Perez-Cruz, G. Piella, G. Sanroma, N. Bargallo, J. Deprest, M.A. Gonzalez Ballester, E. Gratacos and E. EixarchAmerican Journal of Neuroradiology September 2019, 40 (9) 1567-1574; DOI: https://doi.org/10.3174/ajnr.A6165
Enakshy Rajan, J.
- FELLOWS' JOURNAL CLUBSpineYou have accessComparative Analysis of Volumetric High-Resolution Heavily T2-Weighted MRI and Time-Resolved Contrast-Enhanced MRA in the Evaluation of Spinal Vascular MalformationsS.K. Kannath, S. Mandapalu, B. Thomas, J. Enakshy Rajan and C. KesavadasAmerican Journal of Neuroradiology September 2019, 40 (9) 1601-1606; DOI: https://doi.org/10.3174/ajnr.A6164
The authors compared the efficacy of volumetric high-resolution heavily T2-weighted and time-resolved contrast-enhanced images in spinal vascular malformation diagnosis and feeder characterization and assessed whether a combined evaluation improved the overall accuracy of diagnosis in 28 patients. Both sequences demonstrated 100% sensitivity and 93.5% accuracy for the detection of spinal vascular malformations. Volumetric high-resolution heavily T2-weighted imaging was superior to time-resolved contrast-enhanced MR imaging for identification of spinal cord arteriovenous malformations while the opposite was observed for perimedullary arteriovenous fistulas. Both sequences showed equal sensitivity (100%) and accuracy (87%) for spinal dural arteriovenous fistulas. They conclude that combined volumetric high-resolution heavily T2-weighted imaging and time-resolved contrast-enhanced MR imaging can improve the sensitivity and accuracy of spinal vascular malformation diagnosis, classification, and feeder characterization.
Endres, J.
- InterventionalYou have accessQuantitative and Qualitative Comparison of 4D-DSA with 3D-DSA Using Computational Fluid Dynamics Simulations in Cerebral AneurysmsS. Lang, P. Hoelter, A.I. Birkhold, M. Schmidt, J. Endres, C. Strother, A. Doerfler and H. LueckingAmerican Journal of Neuroradiology September 2019, 40 (9) 1505-1510; DOI: https://doi.org/10.3174/ajnr.A6172