1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
RT Journal Article
SR Electronic
T1 Stent-Coil Treatment of a Distal Internal Carotid Artery Dissecting Pseudoaneurysm on a Redundant Loop by Use of a Flexible, Dedicated Nitinol Intracranial Stent
JF American Journal of Neuroradiology
JO Am. J. Neuroradiol.
FD American Society of Neuroradiology
SP 333
OP 337
VO 25
IS 2
A1 Pride, G. Lee
A1 Replogle, Robert E.
A1 Rappard, George
A1 Graybeal, Christopher L. Taylor Dion
A1 White, Jonathan
A1 Purdy, Phillip
YR 2004
UL http://www.ajnr.org/content/25/2/333.abstract
AB Summary: Treatment of dissecting pseudoaneurysms of the distal cervical internal carotid artery with preservation of the parent artery by using stents or coils has become routine. Tortuosity remains a significant obstacle to successful endovascular treatment in some cases. We report the use of a stent-coil technique to treat a nonhealing dissecting pseudoaneurysm and associated stenosis with anatomic preservation of a redundant loop involving the stented arterial segment. This was accomplished by using a Neuroform dedicated intracranial stent.