1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
RT Journal Article
SR Electronic
T1 CTA and CTP for Detecting Distal Medium Vessel Occlusions: A Systematic Review and Meta-analysis
JF American Journal of Neuroradiology
JO Am. J. Neuroradiol.
FD American Society of Neuroradiology
SP 51
OP 56
DO 10.3174/ajnr.A8080
VO 45
IS 1
A1 Sousa, João André
A1 Sondermann, Anton
A1 Bernardo-Castro, Sara
A1 Varela, Ricardo
A1 Donato, Helena
A1 Sargento-Freitas, João
YR 2024
UL http://www.ajnr.org/content/45/1/51.abstract
AB BACKGROUND: The optimal imaging method for detecting distal medium vessel occlusions (DMVOs) remains undefined.PURPOSE: The objective of this study is to compare the diagnostic performance of CTA with CTP in detecting DMVOs.DATA SOURCES: We searched PubMed, EMBASE, Web of Science Core Collection, and Cochrane Central Register of Controlled Trials up to March 31, 2023 (PROSPERO: CRD42022344006).STUDY SELECTION: A total of 12 studies reporting accuracy values of CTA and/or CTP were included, comprising 2607 patients with 479 cases (18.3%) of DMVOs.DATA ANALYSIS: Pooled sensitivity and specificity of both imaging methods were compared using a random-effects model. Subgroup analyses were performed based on the technique used in CTA (multi or single-phase) and the subtype of DMVOs (M2-only vs. M2 and other DMVOs). We applied Quality Assessment of Diagnostic Accuracy (QUADAS-2) tool and Grading of Recommendations, Assessment, Development and Evaluation (GRADE) quality assessment criteria.DATA SYNTHESIS: CTA demonstrated significantly lower sensitivity compared to CTP in detecting DMVOs [0.74, 95%CI (0.63–0.82) vs. 0.89, 95% CI (0.82–0.93), P < 0.01]. When subgrouped into single-phase and multi-phase CTA, multi-phase CTA exhibited higher sensitivity for DMVO detection than single-phase CTA [0.91, 95%CI (0.85–0.94) vs. 0.64, 95%CI (0.56–0.71), P < .01], while reaching similar levels to CTP. The sensitivity of single-phase CTA substantially decreased when extending from M2 to other non-M2 DMVOs [0.74, 95%CI (0.63–0.83) vs. 0.61, 0.95%CI (0.53–0.68), P = .02].LIMITATIONS: We identified an overall high risk of bias and low quality of evidence, attributable to the design and reference standards of most studies.CONCLUSIONS: Our findings highlight a significantly lower sensitivity of single-phase CTA compared to multi-phase CTA and CTP in diagnosing DMVOs.DMVOdistal medium vessel occlusionEVTendovascular treatmentGRADEGrading of Recommendations, Assessment, Development and EvaluationmpCTAmultiphase CT angiographyQUADAS-2Quality Assessment of Diagnostic AccuracySCAsuperior cerebellar arteryspCTAsingle-phase CTATmaxtime-to-maximum