1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
PT  - JOURNAL ARTICLE
AU  - Rao, Dinesh
AU  - Murray, John V.
AU  - Agarwal, Amit K.
AU  - Sandhu, Sukhwinder Johnny
AU  - Rhyner, Pat A.
TI  - Comprehensive Review of External and Middle Ear Anatomy on Photon-Counting CT
AID  - 10.3174/ajnr.A8359
DP  - 2024 Dec 01
TA  - American Journal of Neuroradiology
PG  - 1857--1864
VI  - 45
IP  - 12
4099  - http://www.ajnr.org/content/45/12/1857.short
4100  - http://www.ajnr.org/content/45/12/1857.full
SO  - Am. J. Neuroradiol.2024 Dec 01; 45
AB  - SUMMARY: Photon-counting CT (PCT) allows for improved spatial and contrast resolution compared with traditional energy-integrating detector CT. PCT offers markedly improved visualization of previously described structures, as well as those that were previously beyond the resolution of imaging. Although the anatomic details of the external ear and middle ear structures have been described previously, the rich detail of these structures has not been comprehensively reviewed in the radiology literature. The microarchitecture of the middle ear ossicles and bony protuberances are particularly well visualized on PCT. This review updates the existing literature with a detailed anatomic review of the external ear and the middle ear on temporal bone CT.EACexternal auditory canalEIDenergy-integrating detectorPCTphoton-counting CTTMJtemporomandibular joint