1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
RT Journal Article
SR Electronic
T1 Perfusion-sensitive MR Imaging of Gliomas: Comparison between Gradient-echo and Spin-echo Echo-planar Imaging Techniques
JF American Journal of Neuroradiology
JO Am. J. Neuroradiol.
FD American Society of Neuroradiology
SP 1306
OP 1315
VO 22
IS 7
A1 Sugahara, Takeshi
A1 Korogi, Yukunori
A1 Kochi, Masato
A1 Ushio, Yukitaka
A1 Takahashi, Mutsumasa
YR 2001
UL http://www.ajnr.org/content/22/7/1306.abstract
AB BACKGROUND AND PURPOSE: The different sensitivities to vessel size of gradient-echo echo-planar imaging (GE-EPI) and spin-echo EPI (SE-EPI) might indicate the relative cerebral blood volumes (rCBVs) of different tumor sizes. The techniques of GE-EPI and SE-EPI were compared for detecting low- versus high-grade gliomas.METHODS: Six patients with low-grade gliomas and 19 patients with high-grade gliomas underwent two perfusion-sensitive MR procedures, one produced by a GE- and the other by an SE-EPI technique. Maximum rCBV ratios normalized with rCBV of contralateral white matter were calculated for evaluation. P < .05 was considered statistically significant.RESULTS: Maximum rCBV ratios of high-grade gliomas obtained with the GE-EPI technique (mean, 5.0 ± 2.9) were significantly higher than those obtained with the SE-EPI technique (mean, 2.9 ± 2.3) (P = .02). Maximum rCBV ratios of low-grade gliomas obtained with the GE-EPI technique (mean, 1.2 ± 0.7) were almost equal to those obtained with the SE-EPI technique (mean, 1.2 ± 0.6), and there was no significant difference (P = .66). The difference in the maximum rCBV ratios between the low- and high-grade gliomas reached significance when obtained with the GE-EPI technique (P = .01).CONCLUSION: The GE-EPI technique seems more useful for detecting low- versus high-grade gliomas than the SE-EPI technique.