1naresh
Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => FreeToRead [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) RT Journal Article SR Electronic T1 Small Pipes: Preliminary Experience with 3-mm or Smaller Pipeline Flow-Diverting Stents for Aneurysm Repair prior to Regulatory Approval JF American Journal of Neuroradiology JO Am. J. Neuroradiol. FD American Society of Neuroradiology SP 557 OP 561 DO 10.3174/ajnr.A4170 VO 36 IS 3 A1 Martin, A.R. A1 Cruz, J.P. A1 O'Kelly, C. A1 Kelly, M. A1 Spears, J. A1 Marotta, T.R. YR 2015 UL http://www.ajnr.org/content/36/3/557.abstract AB SUMMARY: Flow diversion has become an established treatment option for challenging intracranial aneurysms. The use of small devices of ≤3-mm diameter remains unapproved by major regulatory bodies. A retrospective review of patients treated with Pipeline Embolization Devices of ≤3-mm diameter at 3 Canadian institutions was conducted. Clinical and radiologic follow-up data were collected and reported. Twelve cases were treated with ≥1 Pipeline Embolization Device of ≤3-mm diameter, including 2 with adjunctive coiling, with a median follow-up of 18 months (range, 4–42 months). One patient experienced a posttreatment minor complication (8%) due to an embolic infarct. No posttreatment hemorrhage or delayed complications such as in-stent stenosis/thrombosis were observed. Radiologic occlusion was seen in 9/12 cases (75%) and near-occlusion in 2/12 cases (17%). Intracranial aneurysm treatment with small-diameter flow-diverting stents provided safe and effective aneurysm closure in this small selected sample. These devices should be further studied and considered for regulatory approval. PEDPipeline Embolization DevicePICAposterior inferior cerebellar artery