1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
RT Journal Article
SR Electronic
T1 Small Pipes: Preliminary Experience with 3-mm or Smaller Pipeline Flow-Diverting Stents for Aneurysm Repair prior to Regulatory Approval
JF American Journal of Neuroradiology
JO Am. J. Neuroradiol.
FD American Society of Neuroradiology
SP 557
OP 561
DO 10.3174/ajnr.A4170
VO 36
IS 3
A1 Martin, A.R.
A1 Cruz, J.P.
A1 O'Kelly, C.
A1 Kelly, M.
A1 Spears, J.
A1 Marotta, T.R.
YR 2015
UL http://www.ajnr.org/content/36/3/557.abstract
AB SUMMARY: Flow diversion has become an established treatment option for challenging intracranial aneurysms. The use of small devices of ≤3-mm diameter remains unapproved by major regulatory bodies. A retrospective review of patients treated with Pipeline Embolization Devices of ≤3-mm diameter at 3 Canadian institutions was conducted. Clinical and radiologic follow-up data were collected and reported. Twelve cases were treated with ≥1 Pipeline Embolization Device of ≤3-mm diameter, including 2 with adjunctive coiling, with a median follow-up of 18 months (range, 4–42 months). One patient experienced a posttreatment minor complication (8%) due to an embolic infarct. No posttreatment hemorrhage or delayed complications such as in-stent stenosis/thrombosis were observed. Radiologic occlusion was seen in 9/12 cases (75%) and near-occlusion in 2/12 cases (17%). Intracranial aneurysm treatment with small-diameter flow-diverting stents provided safe and effective aneurysm closure in this small selected sample. These devices should be further studied and considered for regulatory approval. PEDPipeline Embolization DevicePICAposterior inferior cerebellar artery