1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
RT Journal Article
SR Electronic
T1 Silk Flow-Diverter Stent for the Treatment of Intracranial Aneurysms: A Series of 58 Patients with Emphasis on Long-Term Results
JF American Journal of Neuroradiology
JO Am. J. Neuroradiol.
FD American Society of Neuroradiology
SP 542
OP 546
DO 10.3174/ajnr.A4143
VO 36
IS 3
A1 Lubicz, B.
A1 Van der Elst, O.
A1 Collignon, L.
A1 Mine, B.
A1 Alghamdi, F.
YR 2015
UL http://www.ajnr.org/content/36/3/542.abstract
AB BACKGROUND AND PURPOSE: The Silk flow-diverter stent is increasingly used to treat complex intracranial aneurysms including wide-neck, fusiform aneurysms. Sparse data are available concerning long-term results of this technique. We report our 5-year experience with Silk stent treatment of intracranial aneurysms. MATERIALS AND METHODS: A retrospective review of our prospectively maintained database identified all patients treated by the Silk stent in 2 institutions. Clinical charts, procedural data, and angiographic results were reviewed. RESULTS: Between July 2009 and May 2014, we identified 58 patients with 70 intracranial aneurysms. Endovascular treatment was successful in 93% of patients with 32 treated with the first-generation Silk stent and 26 with the new Silk+ stent. Mean follow-up in 47 patients was 22 months. Despite an 11% delayed complication rate, overall permanent neurologic morbidity was 5.5%. All complications were seen with the first-generation Silk stent. There was no procedure-related mortality. Long-term anatomic results showed 73% with complete occlusion, 16% with neck remnants, and 11% with incomplete occlusion. No recanalization or retreatment was performed. The midterm intrastent stenosis rate was 57%, of which 60% improved or disappeared, 28% were stable, and 12% led to vessel occlusion. Seventy-four percent of stenosis and all vessel occlusions occurred with the first-generation Silk stent. CONCLUSIONS: Endovascular treatment of complex intracranial aneurysms with the Silk stent is an effective therapeutic option. Despite a high rate of delayed complications with the first-generation stents, the current Silk+ stent appears safer. This treatment achieves a high rate of adequate and stable occlusion at long-term follow-up. CLARITYClinical and Anatomical Results in the Treatment of Ruptured Intracranial AneurysmsPAOparent artery occlusion