1naresh
Array
(
[urn:ac.highwire.org:guest:identity] => Array
(
[runtime-id] => urn:ac.highwire.org:guest:identity
[type] => guest
[service-id] => ajnr-ac.highwire.org
[access-type] => Controlled
[privilege] => Array
(
[urn:ac.highwire.org:guest:privilege] => Array
(
[runtime-id] => urn:ac.highwire.org:guest:privilege
[type] => privilege-set
[privilege-set] => GUEST
)
)
[credentials] => Array
(
[method] => guest
)
)
)
1nareshArray
(
[urn:ac.highwire.org:guest:identity] => Array
(
[runtime-id] => urn:ac.highwire.org:guest:identity
[type] => guest
[service-id] => ajnr-ac.highwire.org
[access-type] => OpenAccess
[privilege] => Array
(
[urn:ac.highwire.org:guest:privilege] => Array
(
[runtime-id] => urn:ac.highwire.org:guest:privilege
[type] => privilege-set
[privilege-set] => GUEST
)
)
[credentials] => Array
(
[method] => guest
)
)
)
RT Journal Article
SR Electronic
T1 Usefulness of Non–Contrast-Enhanced MR Angiography Using a Silent Scan for Follow-Up after Y-Configuration Stent-Assisted Coil Embolization for Basilar Tip Aneurysms
JF American Journal of Neuroradiology
JO Am. J. Neuroradiol.
FD American Society of Neuroradiology
SP 577
OP 581
DO 10.3174/ajnr.A5033
VO 38
IS 3
A1 Takano, N.
A1 Suzuki, M.
A1 Irie, R.
A1 Yamamoto, M.
A1 Hamasaki, N.
A1 Kamagata, K.
A1 Kumamaru, K.K.
A1 Hori, M.
A1 Oishi, H.
A1 Aoki, S.
YR 2017
UL http://www.ajnr.org/content/38/3/577.abstract
AB BACKGROUND AND PURPOSE: Y-configuration stent-assisted coil embolization is used for treating wide-neck aneurysms. Noninvasive alternatives to x-ray DSA for follow-up after Y-configuration stent-assisted coil embolization treatment are required. This study aimed to assess the usefulness of non–contrast-enhanced MRA by using a Silent Scan (silent MRA) for follow-up after Y-configuration stent-assisted coil embolization for basilar tip aneurysms.MATERIALS AND METHODS: Seven patients treated with Y-configuration stent-assisted coil embolization for basilar tip aneurysms underwent silent MRA, 3D TOF-MRA, and DSA. Silent MRA and 3D TOF-MRA images were obtained during the same scan session on a 3T MR imaging system. Two neuroradiologists independently reviewed both types of MRA images and subjectively scored the flow in the stents on a scale of 1 (not visible) to 5 (nearly equal to DSA) by referring to the latest DSA image as a criterion standard. Furthermore, we evaluated the visualization of the neck remnant.RESULTS: In all patients, the 2 observers gave a higher score for the flow in the stents on silent MRA than on 3D TOF-MRA. The average score ± standard deviation was 4.07 ± 0.70 for silent MRA and 1.93 ± 0.80 (P < .05) for 3D TOF-MRA. Neck remnants were depicted by DSA in 5 patients. In silent MRA, neck remnants were depicted in 5 patients, and visualization was similar to DSA; however, in 3D TOF-MRA, neck remnants were depicted in only 1 patient.CONCLUSIONS: Silent MRA might be useful for follow-up after Y-configuration stent-assisted coil embolization.BAbasilar arteryCE-MRAcontrast-enhanced MRAPCAposterior cerebral arteryUTEultrashort echo time