1naresh2naresh
Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) [29208222-3745-44a9-9bc7-b0904c06090b] => Array ( [runtime-id] => 29208222-3745-44a9-9bc7-b0904c06090b [type] => toll-free-key [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [3e1480db-eb4d-4a34-a500-779a3f3e3694] => Array ( [runtime-id] => 3e1480db-eb4d-4a34-a500-779a3f3e3694 [type] => toll-free-key ) ) [credentials] => Array ( [method] => toll-free-key [value] => tf_ipsecsha;fa2cb4da8f4d62f7e8fff675e94bfd641240ac09 ) ) ) 1naresh2nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => FreeToRead [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) [f26888eb-b25d-495d-be6c-6d11a29d76c1] => Array ( [runtime-id] => f26888eb-b25d-495d-be6c-6d11a29d76c1 [type] => toll-free-key [service-id] => ajnr-ac.highwire.org [access-type] => FreeToRead [privilege] => Array ( [3e7e63df-57ba-4c74-ab75-334f9b46b75e] => Array ( [runtime-id] => 3e7e63df-57ba-4c74-ab75-334f9b46b75e [type] => toll-free-key ) ) [credentials] => Array ( [method] => toll-free-key [value] => tf_ipsecsha;fa2cb4da8f4d62f7e8fff675e94bfd641240ac09 ) ) ) PT - JOURNAL ARTICLE AU - Meleka, Sherif AU - Patra, Ajanta AU - Minkoff, Evan AU - Murphy, Kieran TI - Value of CT Fluoroscopy for Lumbar Facet Blocks DP - 2005 May 01 TA - American Journal of Neuroradiology PG - 1001--1003 VI - 26 IP - 5 4099 - http://www.ajnr.org/content/26/5/1001.short 4100 - http://www.ajnr.org/content/26/5/1001.full SO - Am. J. Neuroradiol.2005 May 01; 26 AB - Summary: We compared the diagnostic accuracy of lumbar facet blocks guided by either conventional fluoroscopy or CT fluoroscopy (CTF). Seventy-one blocks were performed with conventional fluoroscopy, and 58 were performed using CTF. Pain scores were measured before and after the procedure. The CTF group had a greater percentage decrease in pain (79.5% ± 31.1%) than did the conventional fluoroscopy group (55.5% ± 38.0%; P < .0005). We conclude lumbar facet blocks by using CTF guidance results in greater diagnostic accuracy than do conventional fluoroscopy.