1naresh2naresh
Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) [04e88ad1-f6e3-40e2-805e-38fc62978707] => Array ( [runtime-id] => 04e88ad1-f6e3-40e2-805e-38fc62978707 [type] => toll-free-key [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [258e556e-e474-4293-8f60-ebd3174d122f] => Array ( [runtime-id] => 258e556e-e474-4293-8f60-ebd3174d122f [type] => toll-free-key ) ) [credentials] => Array ( [method] => toll-free-key [value] => tf_ipsecsha;ba81c2d1b49d0def3a50ef911ab4737b02bf875e ) ) ) 1naresh2nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => FreeToRead [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) [04173e16-a601-4c76-b5dc-a307db58048d] => Array ( [runtime-id] => 04173e16-a601-4c76-b5dc-a307db58048d [type] => toll-free-key [service-id] => ajnr-ac.highwire.org [access-type] => FreeToRead [privilege] => Array ( [b46b2d24-ccf9-4870-8ff7-e05e40f24a56] => Array ( [runtime-id] => b46b2d24-ccf9-4870-8ff7-e05e40f24a56 [type] => toll-free-key ) ) [credentials] => Array ( [method] => toll-free-key [value] => tf_ipsecsha;ba81c2d1b49d0def3a50ef911ab4737b02bf875e ) ) ) PT - JOURNAL ARTICLE AU - Akpek, Sergin AU - Arat, Anil AU - Morsi, Hesham AU - Klucznick, Richard P. AU - Strother, Charles M. AU - Mawad, Michel E. TI - Self-Expandable Stent-Assisted Coiling of Wide-Necked Intracranial Aneurysms: A Single-Center Experience DP - 2005 May 01 TA - American Journal of Neuroradiology PG - 1223--1231 VI - 26 IP - 5 4099 - http://www.ajnr.org/content/26/5/1223.short 4100 - http://www.ajnr.org/content/26/5/1223.full SO - Am. J. Neuroradiol.2005 May 01; 26 AB - BACKGROUND AND PURPOSE: Endovascular treatment of wide-necked aneurysms remains a therapeutic challenge. We conducted this study to evaluate the angiographic results and clinical outcome of patients treated with stent-assisted coiling by using a recently available self-expandable intracranial stent.METHODS: A retrospective review of all patients treated with self-expandable stent-assisted coiling between September 2002 and December 2003 was done. Treatment was attempted in 32 patients with 35 aneurysms. Four of the aneurysms were ruptured. All had either a dome-to-neck ratio less than 2 and/or a neck diameter of 5 mm or larger. Following stent placement, coiling was attempted in 33 of 34 aneurysms. The technical success of the procedure, procedure related complications, and the angiographic results were documented.RESULTS: In 34 of 35 aneurysms, stent deployment across the neck of the aneurysm was successful. Coiling was performed successfully in 30 of 33 aneurysms. In 20 aneurysms, immediate posttreatment angiography showed either total (17%) or satisfactory (50%) occlusion. Procedure-related mortality occurred in one patient (3.1%). Adverse events occurred in eight patients (25%); in three of them permanent neurologic deficit resulted (9.3%). In six patients, thrombus formation occurred within the stented segments during the procedure and reopro infusion was used. Follow-up angiography was available in 12 (40%) of 30 treated aneurysms.CONCLUSION: In our practice use of the self-expandable stent seemed to facilitate endovascular treatment of wide-necked intracranial aneurysms. Difficulty of deployment and stent thrombogenicity are the main drawbacks of the system.