1naresh
Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => FreeToRead [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) PT - JOURNAL ARTICLE AU - Mihara, F AU - Gupta, K L AU - Murayama, S AU - Lee, N AU - Bond, J B AU - Haik, B G TI - MR imaging of malignant uveal melanoma: role of pulse sequence and contrast agent. DP - 1991 Sep 01 TA - American Journal of Neuroradiology PG - 991--996 VI - 12 IP - 5 4099 - http://www.ajnr.org/content/12/5/991.short 4100 - http://www.ajnr.org/content/12/5/991.full SO - Am. J. Neuroradiol.1991 Sep 01; 12 AB - To determine the most sensitive pulse sequence and to clarify the role of each pulse sequence in the MR diagnosis of uveal malignant melanoma, noncontrast T1- and T2-weighted, and postcontrast T1-weighted, spin-echo images were compared blindly and independently by two experienced observers. Thirty uveal malignant melanomas, preselected by ophthalmoscopy and sonography for size greater than 2 mm, were examined with a 1.5-T superconducting MR unit with an orbital surface coil. Fifteen tumor studies were done after the patient was injected with gadopentetate dimeglumine. Postcontrast T1-weighted images were the most sensitive in detecting melanomas, demonstrating tumors 2 mm in height accurately on axial planes and 1.6 mm in height on combined orthogonal planes. The contrast-to-noise ratio between melanoma and vitreous fluid was greatest on postcontrast T1-weighted images (average, 72.1), followed by noncontrast T1-weighted images (average, 32.9), and then by T2-weighted images (average, -21.2). Postcontrast T1-weighted images also proved useful in differentiating melanomas from subretinal fluid collections when combined with noncontrast images. We conclude that postcontrast T1-weighted images are most helpful in detecting small uveal melanomas and in differentiating melanomas from subretinal fluid collections.