1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
RT Journal Article
SR Electronic
T1 Magnetic susceptibility artifact in spin-echo MR imaging of the pituitary gland.
JF American Journal of Neuroradiology
JO Am. J. Neuroradiol.
FD American Society of Neuroradiology
SP 1301
OP 1308
VO 13
IS 5
A1 Sakurai, K
A1 Fujita, N
A1 Harada, K
A1 Kim, S W
A1 Nakanishi, K
A1 Kozuka, T
YR 1992
UL http://www.ajnr.org/content/13/5/1301.abstract
AB PURPOSE To evaluate the magnetic susceptibility effect on spin-echo MR images of the pituitary gland.METHODS Air-in-water phantom experiments and studies in normal volunteers were performed using various sampling bandwidth (8.3-33.3 kHz) spin-echo sequences with the polarity of the readout gradient normal or reversed.RESULTS Attachment of a sphenoid septum to the sellar floor was the major factor in the appearance of the inferior surface of the pituitary gland. Patterns of distortion and/or artifactual signal intensities, related to the presence or absence of the attachment, were accentuated on the images with narrower bandwidth. A "spearhead shape" deformity of the sphenoid sinus was observed both in the air-in-water phantom experiment, and when no sphenoid septum was present. When a sphenoid septum was present, two spearhead shapes side by side were present. High-intensity artifacts were seen where the sellar floor was misplaced into the pituitary gland.CONCLUSION Knowledge of the patterns of distortion and high-intensity artifact is important in the diagnosis of pituitary lesions.