RT Journal Article
SR Electronic
T1 A technique for core biopsies of head and neck masses.
JF American Journal of Neuroradiology
JO Am. J. Neuroradiol.
FD American Society of Neuroradiology
SP 518
OP 520
VO 15
IS 3
A1 Mukherji, S K
A1 Turetsky, D
A1 Tart, R P
A1 Mancuso, A A
YR 1994
UL http://www.ajnr.org/content/15/3/518.abstract
AB A technique for performing core biopsies of indeterminate masses of the extracranial head and neck is described. Four patients with suspicious masses of the extracranial head and neck underwent coaxial core biopsies through an 18-gauge Hawkins-Akins blunt tip needle. Three of the four patients had diagnostically adequate samples. There were no neurologic or vascular complications.