1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
RT Journal Article
SR Electronic
T1 Complex-Shaped Platinum Coils for Brain Aneurysms: Higher Packing Density, Improved Biomechanical Stability, and Midterm Angiographic Outcome
JF American Journal of Neuroradiology
JO Am. J. Neuroradiol.
FD American Society of Neuroradiology
SP 1395
OP 1400
DO 10.3174/ajnr.A0542
VO 28
IS 7
A1 Wakhloo, A.K.
A1 Gounis, M.J.
A1 Sandhu, J.S.
A1 Akkawi, N.
A1 Schenck, A.E.
A1 Linfante, I.
YR 2007
UL http://www.ajnr.org/content/28/7/1395.abstract
AB BACKGROUND AND PURPOSE: Five to 60% of coiled brain aneurysms recanalize, generally because of coil compaction. In vitro exclusive use of complex-shaped coils allows better packing of the aneurysmal sac and the neck as compared with helical coils. We report a single-center, prospective study using complex coils. Safety, packing density, and recanalization rate were evaluated.MATERIALS AND METHODS: Seventy-seven aneurysms were embolized using complex coils alone. Aneurysms had a volume of 265 mm3 (diameter: 7.1 ± 3.3 mm) and a neck size of 4.1 ± 1.8 mm (range: 1.5–12 mm). Average follow-up available in 31 patients was 10.5 ± 7.6 months (range: 3–36 months). Primary angiographic endpoints included aneurysmal recanalization and (re)rupture. Primary adverse events included stroke or death.RESULTS: Complete or near-complete occlusion was achieved in all of the aneurysms but required balloon assistance in 24.6%. The packing density was computed as 37% ± 13%. No rerupture was observed during the follow-up interval. Recanalization was seen in 4 (12.9%) of 31. Two basilar tip aneurysms underwent a safe and complete recoiling. Periprocedural nondevice-related neurologic deficits were seen in 2 (2.9%) of 69 patients.CONCLUSIONS: The use of complex-shaped coils allows higher packing density, which may improve the recanalization rate. Basilar tip aneurysms remain a challenge.