1naresh2naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

    [0e08df17-f551-485b-80f7-67846c700388] => Array
        (
            [runtime-id] => 0e08df17-f551-485b-80f7-67846c700388
            [type] => toll-free-key
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [eefe0f1b-9706-4a94-9225-55ddd594d062] => Array
                        (
                            [runtime-id] => eefe0f1b-9706-4a94-9225-55ddd594d062
                            [type] => toll-free-key
                        )

                )

            [credentials] => Array
                (
                    [method] => toll-free-key
                    [value] => tf_ipsecsha;98a7fe36a65ad7afbe506899d309c725101f0b36
                )

        )

)
1naresh2naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

    [65b90031-5c11-4534-91ff-4790e34e56dd] => Array
        (
            [runtime-id] => 65b90031-5c11-4534-91ff-4790e34e56dd
            [type] => toll-free-key
            [service-id] => ajnr-ac.highwire.org
            [access-type] => FreeToRead
            [privilege] => Array
                (
                    [aed837ae-ee84-4c87-92b0-bbaeacdfc58d] => Array
                        (
                            [runtime-id] => aed837ae-ee84-4c87-92b0-bbaeacdfc58d
                            [type] => toll-free-key
                        )

                )

            [credentials] => Array
                (
                    [method] => toll-free-key
                    [value] => tf_ipsecsha;98a7fe36a65ad7afbe506899d309c725101f0b36
                )

        )

)
PT  - JOURNAL ARTICLE
AU  - Maldonado, I.L.
AU  - Machi, P.
AU  - Costalat, V.
AU  - Mura, T.
AU  - Bonafé, A.
TI  - Neuroform Stent−Assisted Coiling of Unruptured Intracranial Aneurysms: Short- and Midterm Results from a Single-Center Experience with 68 Patients
AID  - 10.3174/ajnr.A2245
DP  - 2011 Jan 01
TA  - American Journal of Neuroradiology
PG  - 131--136
VI  - 32
IP  - 1
4099  - http://www.ajnr.org/content/32/1/131.short
4100  - http://www.ajnr.org/content/32/1/131.full
SO  - Am. J. Neuroradiol.2011 Jan 01; 32
AB  - BACKGROUND AND PURPOSE: Intracranial stent placement assists in the coiling of wide-neck aneurysms and aids in reconstructing and protecting the parent artery. In this study, we analyze our experience in the use of the Neuroform system. MATERIALS AND METHODS: Records of patients treated with a Neuroform stent from June 2003 to September 2007 were retrieved from a data base for analysis of population characteristics, occurrence of complications, and acute and midterm angiographic results. RESULTS: Sixty-eight patients harboring 76 aneurysms located primarily in the anterior circulation were treated. There were 5 cases (6.6%) of clot formation after deployment (1 with a permanent neurologic deficit), 1 case of perioperative stent displacement with hemorrhage, and 5 cases (6.6%) of transient neurologic deficit due to thromboembolic events. The morbidity-mortality rate at discharge was 2.9%. One patient presented with a delayed in-stent thrombosis, and 3 others, with silent stenosis. Twenty-four aneurysms (31.6%) were completely occluded in the initial embolization. However, a marked increase in the occlusion rate was observed, with 44 of the 68 aneurysms (64.7%) examined at the 18-month follow-up and 26 of the 46 aneurysms (56.5%) examined in the 3-year follow-up presenting with complete occlusion. At the end of the study, a neck remnant was present in 6 aneurysms (13%) and a residual sac, in 7 (15.2%). Mean follow-up time was 25.7 months. CONCLUSIONS: The present series demonstrates the relative safety and feasibility of the Neuroform stent−assisted coiling technique, which seems to provide better results over coiling alone for wide-neck aneurysms. Angiographic results improve with time due to progressive thrombosis of the aneurysm. ASAaspirinCIconfidence intervalDlargest aneurysm diameterDSAdigital subtraction angiographyGDCGuglielmi detachable coilICAinternal carotid arteryMCAmiddle cerebral arteryMRAMR angiographyORodds ratioPICAposterior inferior cerebellar artery