Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )Table 3:Agreement in MR imaging interpretation between an experienced multidisciplinary consensus group and each of 4 neuroradiologistsa
More Experienced Less Experienced Rater 1 Rater 2 Rater 3 Rater 4 Conventional CE-MR imaging 0.53 (0.31–0.75) 0.70 (0.50–0.91) 0.63 (0.43–0.84) 0.58 (0.36–0.80) CE-MR imaging + ASL-CBF 0.58 (0.36–0.80) 0.69 (0.48–0.89) 0.61 (0.39–0.82) 0.65 (0.44–0.86) CE-MR imaging + DSC-rCBV 0.58 (0.36–0.80) 0.71 (0.51–0.90) 0.63 (0.42–0.84) 0.68 (0.47–0.88) CE-MR imaging + DSC-FTB 0.66 (0.46–0.87) 0.80 (0.63–0.97) 0.66 (0.46–0.86) 0.73 (0.55–0.92)
↵a All analyses showed P < .001. Values are Cohen κ with 95% confidence intervals in the parentheses.