Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )Table 2:Signal intensity and enhancement characteristics of 34 chronically thrombosed, partially recanalized venous segments
Signal Intensity T1WI T2WI PD-WI FLAIR GRE Enhancement Degree* Hypointense 2 (5.9%) 0 (0%) 0 (0%) 0 (0%) 0 (0%) Less 5 (15.6%) Isointense 29 (85.3%) 1 (3.0%) 0 (0%) 2 (6.9%) 7 (50%) Equal 13 (40.6%) Hyperintense 3 (8.8%) 33 (97.0%) 5 (100%) 27 (93.1%) 7 (50%) Greater 14 (43.8%)
Note:—34 segments were imaged with T1-weighted (T1WI) and fast spin-echo T2-weighted (T2WI) sequences, 29 segments were imaged using fluid-attenuated inversion recovery sequences (FLAIR), 7 segments with proton density weighted sequences (PD-WI), and 14 segments with gradient recalled-echo (GRE) sequences. Thrombus signal intensity was graded relative to normal gray matter.
* Enhancement was graded as less than, equal to, or greater than venographically normal sinus enhancement.