1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)

CTA protocol

CTA RoutineCTA Postclipping
Pre-CTARoutine head precontrastRoutine head precontrast
CoverageC1–2 to 2 cm below the inner table of the vertexC1–2 to 2 cm below the inner table of the vertex
AcquisitionHelicalHelical
Detectors16i (64i)16i (64i)
Rotation time0.6 seconds0.6 seconds
Section thickness0.625 mm0.625 mm
Pitch0.938:1 (0.969:1)0.562:1 (0.531:1)
Table speed9.38 cm/s (19.37 cm/s)5.62 cm/s (10.62 cm/s)
Scanning FOV25 cm (32 cm)25 cm (32 cm)
kV(p)120120
mA750750
Display FOV15 cm15 cm
AlgorithmStandardStandard
Contrast injectionDual injector: 50-mL Omnipaque 300,* 4 mL/s; 40 mL saline, 2.5 mL/sDual injector: 50 mL Omnipaque 300,* 4 mL/s; 40 mL saline, 2.5 mL/s
ReconstructionSagittal and coronal MPRs, 2.5 mm thick × 2.0-mm spacingSagittal and coronal MPRs, 2.5 mm thick × 2.0-mm spacing
  • Note:—MPR indicates multiplanar reconstruction image; FOV, field of view.

  • * Omnipaque 300 (iohexol), GE Health, Piscataway, NJ.