Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )Summary of data for 92 Wingspan stents with imaging follow-up
Location Younger (≤55 years)* Older (>55 years)† Lesions with Imaging Follow-Up In-Stent Restenosis Lesions with Imaging Follow-Up In-Stent Restenosis Anterior circulation 26 13 29 9 ICA 17 10 15 4 Supraclinoid segment 9 8 6 2 Posterior circulation 5 1 33 6
* Thirty-one patent stents (29 patients); mean age, 48.1 years; age range, 35–55 years.
† Sixty-two patent stents (59 patients); mean age, 68.4 years; age range, 56–84 years.