1naresh
Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )Table 2:Detection rates of the artery of Adamkiewicz
Method (Reference) Detection Rate, % (n/N) Confirmation Rate, % (n/N) Detectors Row Phase Scan Duration Injection Rate Seconds mL/s IVCTA (19) 90 (63/70) 32 (20/63) 4 1 40 3.5 IVCTA (20) 90 (9/10) 89 (8/9) 8 1 40 4.0–4.5 IVCTA (18) 83 (25/30) 72 (18/25) 16 1 NA 3.5 IACTA (24) 100 (39/39) 90 (35/39) 4 or 6 1 NA 4.0–7.0 IVCTA (present study) 60 (9/15) 56 (5/9) 16 2 25 5.0 IACTA (present study) 94 (16/17) 88 (14/16) 16 2 25 5.0
Note:—IVCTA indicates intravenous CT angiography; IACTA, intra-arterial CT angiography; NA, not assessed.