1naresh
Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )Table 3:AUC and comparisons between imaging techniques for 2 readers and 53 sites of cerebral venous thrombosis in 39 patients
AUC Estimate Pair-wise Difference, P Value Reader 1 Reader 2 Average (95% CI) All veins Combo-4D MRV 0.94 0.90 0.92 (0.88–0.96) a(.03), b(.03) TOF MRV 0.92 0.93 0.93 (0.88–0.97) c(.005), d(.02) GRE 0.83 0.89 0.86 (0.81–0.91) T2W 0.85 0.83 0.84 (0.78–0.91) Dural venous sinuses Combo-4D MRV 0.98 1.00 0.99 (0.97–1.00) a(.005), b(<.001) TOF MRV 0.95 0.96 0.96 (0.92–1.00) c(.01), d(<.001) GRE 0.81 0.87 0.84 (0.79–0.89) T2W 0.89 0.91 0.90 (0.84–0.96) Cortical veins Combo-4D MRV 0.87 0.73 0.80 (0.70–0.90) TOF MRV 0.87 0.90 0.89 (0.78–0.99) c(.01), e(.02) GRE 0.85 0.91 0.88 (0.78–0.97) T2W 0.77 0.70 0.74 (0.60–0.87)
Note:—Superscripts a, b, c, d, and e indicate significant differences between combo-4D MRV and T2W, combo-4D MRV and GRE, TOF MRV and T2W, TOF MRV and GRE, and between TOF MRV and combo-4D MRV, respectively.