Table 4:

Venous study in TR-3D-CE-MRA for patients with pathology

VeinsaInterobserver Agreement (κ)Mean Visibility Score (/2)Sensitivity for Detection (%)
SSS1.002100.0
TS1.002100.0
SR1.002100.0
Great cerebral1.002100.0
ISS0.851.1490.9
Internal cerebral0.300.77100.0
Basal0.121.4195.4
  • a Veins are listed in decreasing order of reproducibility: interobserver agreement, mean visibility score, and sensitivity of TR-3D-CE-MRA for detection.