1naresh
Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )TABLEComparison of the freehand technique with the stereotactic device technique
Variable Freehand Stereotactic Device No. of patients 8 8 Skin entry-point verification (min) 17.5 4 Sterile setup time (min) 24.9 13 Needle aligned with vector (min) 27.6 18.8 Needle in target (min) 36.9 25.3 Total no. of images 14 7.9 Distance of skin entry point (mm) 4.5 0 Distance off target (mm) 4.8 1.6 Depth to target (mm) 79.8 73.1