1naresh
Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )TABLE 2:Overview of diagnostic workup results, therapeutic course, angiographic follow-up findings, and outcome
Patient No./Age (y)/Sex Surgical Treatment Endovascular Treatment First DSA Finding Second DSA Finding Superselect DSA Course of Treatment Follow-up Angiography* Barthel Index 1/43/F Yes Yes Negative Questionable 2 First DSA findings negative and control DSA findings (1 mo later) questionable. Microcatheterization was diagnostic. Endovascular treatment failed due to clinically uncomplicated vasospasm of the arterial feeder. Surgical intervention was successful. At 6 mo 100 2/31/M No Yes Negative Questionable 3 First DSA findings negative and control DSA findings (1 mo later) questionable. Microcatheterization was diagnostic. First embolization incomplete. Second (6 mo later) endovascular procedure successful. At 3 mo 100 3/60/F No Yes Positive 1 No data At 6 mo 95 4/41/M No Yes Questionable Positive 1 First DSA findings questionable. Repeat angiographic findings (2 mo later) were diagnostic. Single-shot endovascular treatment (1 wk later) successful. At 6 mo 95 5/57/M Yes No Positive 0 No data None 50 6/48/F Yes Yes Positive 1 Surgery attempted first; failed due to inability to locate AV shunt. Postoperative angiograms showed persistence of AV shunt. Endovascular treatment subsequently performed At 6 mo 100 7/43/M Yes No Questionable Positive First DSA findings questionable. Repeat angiography findings (1 mo later) were diagnostic. Subsequently surgery was successful. At 3 mo 100 8/65/F No Yes Questionable Positive 1 First DSA findings questionable. Repeat angiography findings (2 mo later) were diagnostic. Endovascular treatment (1 mo later) successful. At 3 mo 100 9/38/M Yes No Positive 0 No data At 3 mo 100 10/50/F Yes Yes Positive 1 DSA findings diagnostic. Endovascular treatment failed due to suboptimal microcatheter tip positioning. Patient subsequently underwent surgery. Immediate postoperative angiograms confirmed complete AV shunt resection. None 95
Note.—DSA indicates digital subtraction angiography; AV, arteriovenous.
↵* Performed after the last procedure.