TABLE 2:

Pressure and flow in the dome of a surgically created canine aneurysm, injection at 5 mL/s over 4 seconds

CharacteristicBefore GDC PlacementAfter GDC Placement
In VivoIn VitroP ValueIn VivoIn VitroP Value
Increase in pressure P7.4 ± 1.521.0 ± 0.8<.059.5 ± 2.615.2 ± 1.3*<.05
Change in temperature ΔT, °C9.66 ± 0.099.28 ± 0.16>.051.74 ± 0.25*4.45 ± 1.36*<.05
Pressure-flow shift ε, seconds0.30 ± 0.250.33 ± 0.09>.051.68 ± 0.87*0.66 ± 0.19*<.05
Dilution interval, seconds7.32 ± 0.548.21 ± 0.75>.0521.15 ± 1.34*11.33 ± 2.21*<.05
  • Note.—Injections were normal saline at room temperature. Data are the mean ± SD. P values were determined with a two-sided Student t test.

  • * P < .05 before GDC placement versus after GDC placement.