1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)
1naresh
Array
(
    [urn:ac.highwire.org:guest:identity] => Array
        (
            [runtime-id] => urn:ac.highwire.org:guest:identity
            [type] => guest
            [service-id] => ajnr-ac.highwire.org
            [access-type] => Controlled
            [privilege] => Array
                (
                    [urn:ac.highwire.org:guest:privilege] => Array
                        (
                            [runtime-id] => urn:ac.highwire.org:guest:privilege
                            [type] => privilege-set
                            [privilege-set] => GUEST
                        )

                )

            [credentials] => Array
                (
                    [method] => guest
                )

        )

)

TABLE 1:

Summary of glue embolization in rabbit aneurysms

Aneurysm No.GDCGlue Concentration (%)*Amount of Glue Injected (mL)Duration of Injection (min:s)Results2-month Follow-upComments
1500.62:28CompleteComplete
2500.52:30IncompleteDecreased residual sac
3400.52:13IncompleteND
4400.61:26Occlusion of parent arteryNo changeLeakage of glue during retrieval of microcatheter.
5330.53:35CompleteND
6330.53:9Occlusion of parent arteryNDLeakage of glue during retrieval of microcatheter.
7280.42:15IncompleteComplete
8280.82:45CompleteND
98 × 20500.21:35IncompleteDecreased residual sac
106 × 10500.445 secondsCompleteND
116 × 15400.438 secondsCompleteComplete
126 × 20400.41:25CompleteComplete
135 × 15330.533 secondsCompleteCompleteSpillage of glue.
145 × 15330.51:55IncompleteND
156 × 20280.31:57CompleteComplete
168 × 20280.62:3CompleteComplete
  • Note.—GDC indicates Guglielmi detachable coil; complete or incomplete, complete or incomplete obliteration of aneurysmal lumen on arteriogram; ND, not done.

  • * Concentration of glue in the mixture to iodized oil.