Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )Table 3:Comparison of the currently reported techniques with 4D-CTA techniques (excluding combined 4D-CTA/CTP techniques) reported by other groups
Report Exposure Duration (sec) Rotation Time (ms) Exposure Parameters Effective Dose (mSv) Brouwer et al (2010)2 22 NS 80 kV, 120 mA 5.1 Hoogenboom et al (2012)11 15 500 80 kV, 240 mA NS Fujiwara et al (2013)3 12a 500 80 kV, 200 mA 5.2 Willems et al (2011)1 and (2012)5 22 1000 80 kV, 100 mA 5.2 D'Orazio et al (2014)10 15 350 80 kV, 120 mA 5.62 This study Estimated duration 15.6 (16 with option to adjust) 750 80 kV, 150 mA 6.9 Measured exposure 10.1 (mean) 1000 80 kV, 100 mA 3.4
Note:—NS indicates not stated.
↵a Ten-second continuous exposure followed by 4 intermittent exposures.