Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )Table 2:ROC of CBV, corrected CBV, and K2 in differentiating PCNSLs from glioblastomasa
Parameter AUC 95% CI P Value CV SEN SPE Accuracy CBV ratio 0.984 0.952–1.000 <.001 1.88 100 86.7 94.2 Corrected CBV ratio 0.940 0.861–1.000 <.001 3.01 90 93.3 91.4 2.08 100 46.7 77.1 K2 0.788 0.624–0.953 .004 1.2 75 80.0 77.1
Note:—CI indicates confidence interval; CV, cutoff value; SEN, sensitivity; SPE, specificity; AUC, area under the curve; ROC, receiver operating characteristic curve analysis.
↵a Data of sensitivity, specificity, and accuracy are in percentages.