Table 2:

Hemodynamic parameters of VAFAs with different stenting strategiesa

Parameters0 Stent1 Stent2 Stents3 StentsP Value
Wall shear stress (%) (n = 10)10092.879.474.2.003
Oscillatory shear index (%) (n = 10)10056.550.562.6.169
Pressure (%) (n = 10)100115.7121.5128.2<.001
Relative residence time (%) (n = 10)100111.3115.4145.0.004
  • a Data are expressed as the median of the variation rate.