Array ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) ) 1nareshArray ( [urn:ac.highwire.org:guest:identity] => Array ( [runtime-id] => urn:ac.highwire.org:guest:identity [type] => guest [service-id] => ajnr-ac.highwire.org [access-type] => Controlled [privilege] => Array ( [urn:ac.highwire.org:guest:privilege] => Array ( [runtime-id] => urn:ac.highwire.org:guest:privilege [type] => privilege-set [privilege-set] => GUEST ) ) [credentials] => Array ( [method] => guest ) ) )Table 2:Inter- and intrareader reproducibility for ADC, D, D*, and f measurementsa
Parameters ICC Interreader Intrareader ADC (×10−3 mm2/s) 0.961 (0.913–0.977) 0.954 (0.871–0.980) D (×10−3 mm2/s) 0.942 (0.860–0.986) 0.936 (0.884–0.975) D* (×10−3 mm2/s) 0.840 (0.762–0.931) 0.848 (0.766–0.909) f (%) 0.908 (0.819–0.965) 0.922 (0.835–0.964)
Note:—ICC indicates intraclass correlation coefficient.