Table 4:

Univariate analysis showing the association between hemorrhagic complications and the technical variables of patients treated by TVE

VariableWere There Hemorrhagic Complications?
No (n = 49)Yes (n = 8)P
Arterial balloon.39a
 Yes113
 No385
No. of embolization sessions,(mean) (SD)1.8 (1.2)1.8 (0.99).50b
Coiled vein1.0a
 Yes152
 No346
Total occlusion (angiographic cure)1.0a
 Yes448
 No50
  • a Fisher exact test.