OtherBRAIN
3D Rotational Digital Subtraction Angiography May Underestimate Intracranial Aneurysms: Findings from Two Basilar Aneurysms
L.-D. Jou, A. Mohamed, D.H. Lee and M.E. Mawad
American Journal of Neuroradiology October 2007, 28 (9) 1690-1692; DOI: https://doi.org/10.3174/ajnr.A0652
L.-D. Jou
A. Mohamed
D.H. Lee

References
- ↵
- ↵
- ↵Ernemann UU, Gronewaller E, Duffner FB, et al. Influence of geometric and hemodynamic parameters on aneurysm visualization during three-dimensional rotational angiography: an in vitro study. AJNR Am J Neuroradiol 2003;24:597–603
- ↵Yamura M, Hirai T, Korogi Y, et al. Quantitative evaluation of measurement accuracy for three-dimensional angiography system using various phantoms. Radiat Med 2005;23:175–81
- ↵Heran NS, Song JK, Namba K, et al. The utility of DynaCT in neuroendovascular procedures. AJNR Am J Neuroradiol 2006;27:330–32
- ↵Sluzewski M, Rooij WJ, Slob MJ, et al. The relationship between aneurysm volume, packing, and compaction in 145 coiled cerebral aneurysms. Radiology 2004;231:653–58
- ↵Ford MD, Alperin N, Lee SH, et al. Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries. Physiol Meas 2005;26:477–88
- ↵
In this issue
Advertisement
3D Rotational Digital Subtraction Angiography May Underestimate Intracranial Aneurysms: Findings from Two Basilar Aneurysms
L.-D. Jou, A. Mohamed, D.H. Lee, M.E. Mawad
American Journal of Neuroradiology Oct 2007, 28 (9) 1690-1692; DOI: 10.3174/ajnr.A0652
Jump to section
Related Articles
- No related articles found.
Cited By...
- Critical role of angiographic acquisition modality and reconstruction on morphometric and haemodynamic analysis of intracranial aneurysms
- The utility of cone beam volume CT in the evaluation of thrombosed intracranial aneurysms in subarachnoid hemorrhage
- In vitro and in silico study of intracranial stent treatments for cerebral aneurysms: effects on perforating vessel flows
- The utility of cone beam volume CT in the evaluation of thrombosed intracranial aneurysms in subarachnoid hemorrhage
- Feasibility of Intravenous Flat Panel Detector CT Angiography for Intracranial Arterial Stenosis
- Patient-Specific Computational Hemodynamics of Intracranial Aneurysms from 3D Rotational Angiography and CT Angiography: An In Vivo Reproducibility Study
- Use of Angiographic CT Imaging in the Cardiac Catheterization Laboratory for Congenital Heart Disease
- DynaCT evaluation of in-stent restenosis following Wingspan stenting of intracranial stenosis
This article has not yet been cited by articles in journals that are participating in Crossref Cited-by Linking.
More in this TOC Section
Similar Articles